Beijingqiyuetianchen Technology Co., Ltd. — Verified Supplier
About Beijingqiyuetianchen Technology Co., Ltd. - Batteries & Chargers Supplier in China
Beijing, China hosts Beijingqiyuetianchen Technology Co., Ltd., which currently lists six active products in its catalogue. The catalogue includes several Leica total‑station models and two Nickel‑Metal Hydride battery products, each assigned to HS code families 8507.80 and 8507.40 respectively. The total‑station models are identified as Leica GEB121 TPS Series, Leica GEB70 TPS Series, Leica GEB77 TC and TPS Series, Leica GEB111 Total Station Battery, and Leica GEB171 TC/TPS/TCA Series Battery. The battery items are described as NiMH cells housed in ABS plastic, matching the HS codes for primary (8507.40) and secondary (8507.80) batteries. This mix places the supplier within the Wires & Cables, Batteries & Chargers, and Battery Testers & Chargers top categories.
Leica total stations are geodetic surveying instruments that combine electronic distance measurement with angular measurement. Typical industry specifications for this class include angular accuracy of 1‑2 arc‑seconds and distance accuracy of 1‑2 mm + 1 ppm over 100 m. The NiMH batteries listed are rechargeable cells, commonly supplied with a nominal voltage of 1.2 V and capacities ranging from 1 500 mAh to 2 500 mAh. Such batteries are often used to power portable surveying equipment and require compliance with safety standards such as IEC 61960 and RoHS restrictions on hazardous substances. The supplier’s product set therefore covers both the instrument hardware and its rechargeable power source.
Product Range and Specialties of Beijingqiyuetianchen Technology Co., Ltd.
The catalogue presents four Leica total‑station models (GEB121 TPS, GEB70 TPS, GEB77 TC/TPS, and GEB70 TPS series) and two NiMH battery variants (GEB111 battery under HS 8507.80 and GEB171 battery under HS 8507.40). In the surveying equipment market, total stations are classified under HS chapter 90 (instruments for measuring length, angle, or direction) and are typically shipped in reinforced wooden cases or anti‑static foam packaging. Buyers usually evaluate these instruments by checking specifications such as measurement range (up to 5 km), angular repeatability, and integrated data‑link interfaces (Bluetooth, USB). NiMH batteries for such devices fall under HS chapter 85 and are evaluated on parameters like nominal voltage, capacity (mAh), charge/discharge cycles, and compliance with IEC 61960 safety testing. Common industry grades for NiMH cells include low‑self‑discharge (LSD) and high‑drain versions, both of which may be required depending on the total‑station’s power consumption.
Trade and Export Information - Beijingqiyuetianchen Technology Co., Ltd.
China is a major exporter of surveying equipment and rechargeable battery cells, with the European Union, North America, and Southeast Asia representing the largest import markets. Total‑station units are generally classified under HS 9015 (surveying instruments) while NiMH batteries are recorded under HS 8507.40 (primary batteries) and HS 8507.80 (other batteries). Importers typically request certifications such as CE marking for electromagnetic compatibility, IEC 61960 test reports for battery safety, and RoHS compliance for restricted substances. Packaging for total stations usually involves custom‑molded foam inserts inside wooden crates or 40‑ft containers, whereas NiMH batteries are packed in anti‑static bags within cardboard cartons, often consolidated into 20‑ft containers for bulk shipments. Standard Incoterms used by Chinese exporters include FOB Shanghai or CIF destination port, with freight forwarders handling customs documentation and HS‑code verification.
Sourcing from Beijingqiyuetianchen Technology Co., Ltd. - Buyer Guidance
When sourcing these Leica total stations, buyers should request the full technical data sheet, calibration certificate, and an IEC 61850 compliance report if electronic interfacing is required. For the NiMH batteries, request the IEC 61960 safety test report, a material safety data sheet (MSDS), and verification of RoHS compliance. Verify that the HS codes on the commercial invoice match the product description (8507.40 for the GEB171 battery, 8507.80 for the GEB111 battery) to avoid customs delays. Typical minimum order quantities for the batteries range from 100 to 500 units, with lead times of 4‑6 weeks from order confirmation, while total‑station units often have a MOQ of one unit and a lead time of 6‑8 weeks due to calibration and testing procedures. Ensure that packaging specifications meet the buyer’s logistics plan, such as anti‑static protection for batteries and shock‑absorbing crates for the total stations.
Frequently Asked Questions About Beijingqiyuetianchen Technology Co., Ltd.
What Leica total‑station models does Beijingqiyuetianchen Technology list?
The supplier lists four models: Leica GEB121 TPS Series, Leica GEB70 TPS Series, Leica GEB77 TC and TPS Series, and Leica GEB70 TPS Series (repeated entry).
Which HS codes are assigned to the battery products?
The GEB111 battery is recorded under HS 8507.80 and the GEB171 battery under HS 8507.40.
What material composition is specified for the NiMH batteries?
Both battery entries describe Nickel‑Metal Hydride cells housed in ABS plastic enclosures.
What certifications should a buyer request for the NiMH batteries?
Buyers should request IEC 61960 safety test reports, RoHS compliance statements, and an MSDS for the battery cells.
What typical packaging is used for the total‑station instruments?
Industry practice is to ship total stations in reinforced wooden crates with custom foam inserts, often loaded in 20‑ft or 40‑ft containers.
What are common lead times for ordering the listed batteries?
Suppliers of NiMH batteries from China usually quote a lead time of 4‑6 weeks for orders between 100 and 500 units.
Which markets most frequently import Chinese surveying equipment?
The European Union, United States, Canada, and Southeast Asian countries are the primary import destinations for Chinese‑made total stations.
What documentation is needed to clear customs for the battery items?
Customs clearance typically requires a commercial invoice with the correct HS code, a test report meeting IEC 61960, and a declaration of RoHS compliance.





























