ABL-Sursum of Germany supplies residual current circuit breakers (RCCBs) designed to interrupt earth-leakage currents within 30 milliseconds. The units feature a flame-retardant ABS/PC thermoplastic housing, electrolytic copper 99.9% contact blades, silver-alloy contacts and a steel magnetic core. They are offered in 2-pole single-phase and 4-pole three-phase configurations. Sensitivity ratings range from 10 mA for personal protection to 300 mA for equipment and fire prevention.
The housing material provides fire resistance while the copper and silver contacts ensure low resistance and reliable tripping. IEC 61008 compliance guarantees that the breakers meet internationally recognised safety performance criteria. In the industry, similar RCCBs typically exhibit a breaking capacity of 6 kA and are rated for 230 V (single-phase) or 400 V (three-phase) systems. These typical specifications align the product with standard electrical distribution requirements worldwide.
Typical buyers include electrical contractors, plant engineers and renewable-energy project developers who need dependable protective devices. ABL-Sursum offers both ODM and OEM services and can supply units under FOB or CIF terms, though exact quantities and lead times must be confirmed with the supplier. Importers should verify certification documents and request sample testing before placing a bulk order.
| Housing Material | Thermoplastic (Flame-retardant ABS/PC) |
| Contact Blade Material | Electrolytic Copper 99.9% |
| Contact Material | Silver Alloy |
| Magnetic Core Material | Steel |
| IEC Standard | IEC 61008 |
| Sensitivity Ratings | 10 mA, 30 mA (typical), 300 mA |
| Pole Configurations | 2-pole single-phase, 4-pole three-phase |
| Typical Breaking Capacity | typical 6 kA |
| Typical Rated Voltage | typical 230 V AC (single-phase), 400 V AC (three-phase) |
| Typical Short-Time Current Rating | typical 10 kA |
ABL-Sursum is located at Ottensooser Str.22, Lauf-A-D-Pegnitz D91207, Germany and is classified as an imported supplier with a harbor trust tier. The profile shows a response rate of 0 % and no recorded average response time, indicating that communication speed may vary. The company lists its product range as residual current circuit breakers and emphasises compliance with IEC and CE certifications. No specific minimum order quantity, price range or lead-time information is provided in the listing.
The supplier highlights the availability of both ODM and OEM manufacturing options, allowing buyers to request custom specifications or branding. While the listing mentions flexible ordering quantities, exact MOQ must be negotiated directly. Shipping terms such as FOB and CIF are indicated, but the exact freight details depend on the buyer’s chosen incoterm. Prospective importers are encouraged to obtain the latest test reports and certification copies from ABL-Sursum.
Residual Current Circuit Breakers (RCCBs/RCDs) are essential safety devices designed to disconnect circuits within 30 milliseconds upon detecting earth leakage currents, preventing lethal electric shocks. Available in 2-pole single-phase and 4-pole three-phase configurations with sensitivity ratings from 10mA for personnel protection to 300mA for equipment and fire prevention. Manufactured to IEC 61008 standards, these breakers are critical components in residential, commercial, and industrial electrical panels worldwide. Widely sourced from manufacturing hubs in Asia for global distribution and installation projects.
| Business Type | Supplier |
| Year Established | Recently Joined |
| Employees | Contact Supplier |
| Annual Revenue | Contact Supplier |
| Main Products | View Products Tab |
| Major Markets | Global |
| Response Time | Contact Supplier |
| Response Rate | New Supplier |
Before placing an order, importers should request the current IEC 61008 test report and the CE conformity certificate to confirm that the RCCBs meet European safety standards. It is advisable to obtain a material data sheet that details the flame-retardant ABS/PC housing composition and the copper-silver contact alloys, as these affect durability and performance. Verifying the supplier’s quality-management system, such as ISO 9001 registration, further reduces risk.
Logistics for German-origin RCCBs typically involve sea freight under FOB or CIF incoterms, with the supplier arranging container loading at nearby ports such as Hamburg or Bremerhaven. Buyers should clarify the expected lead time, which can vary based on order size and customisation requirements, and agree on payment terms, commonly a 30 % advance letter of credit followed by balance upon shipment documentation. Confirming the exact port of discharge helps avoid unexpected handling fees.
Quality assurance can be reinforced by scheduling a pre‑shipment inspection conducted by a third‑party agency familiar with electrical safety devices. The inspection should verify the correct sensitivity rating, pole configuration and visual condition of the housing, as well as functional testing of trip times. Requesting a full test certificate, including short-circuit and residual-current performance data, ensures that the delivered RCCBs conform to the agreed specifications and documentation.
Compare alternatives, find similar products and connect with verified suppliers
When sourcing Residual Current Circuit Breakers for your business, securing the right balance of quality and cost is essential. ABL-Sursum, a verified supplier based in Germany, offers this product with key specifications including Residual Current Circuit Breaker (RCCB / RCD), 2-Pole (Single-Phase) / 4-Pole (Three-Phase), and 16A, 25A, 32A, 40A, 63A, 100A. By purchasing directly from the manufacturer or authorized exporter, buyers can negotiate favorable FOB prices starting at $1285,./Unit and manage bulk orders with a minimum order quantity (MOQ) of 1 Unit. This product is actively traded under HS Code 8536.30, making it a staple in the Electric Circuit Breakers sector with strong demand from importing countries worldwide.
Importing Residual Current Circuit requires careful attention to shipping logistics, customs compliance, and secure payment terms. ABL-Sursum offers flexible shipping options such as Full Container Load (FCL) or Less than Container Load (LCL) via sea freight. To ensure a smooth transaction, buyers should verify import duties for HS Code 8536.30 in their destination country. Common payment methods for international B2B transactions include Letter of Credit (L/C), Telegraphic Transfer (T/T), and Documents against Payment (D/P). All transactions and RFQs are facilitated through EximNext, a leading online B2B marketplace designed to make cross-border trade secure and efficient.
Finding trustworthy partners is the foundation of successful importing. The supplier of this Residual Current Circuit has been verified on our platform. Whether you are a distributor, wholesaler, or procurement manager, you can request a free quotation, ask for product samples, and finalize your bulk purchase with confidence. EximNext hosts thousands of verified manufacturers and exporters across 200+ countries. Explore similar products in the Electric Circuit Breakers category and connect with top-tier exporters on our comprehensive B2B marketplace. Start your sourcing journey today.
Importing Residual Current Circuit requires careful attention to shipping logistics, customs compliance, and secure payment terms. Common shipping options include Full Container Load (FCL) or Less than Container Load (LCL) via sea freight. Buyers should verify import duties for HS Code 8536.30 in their destination country. Common payment methods include Letter of Credit (L/C), Telegraphic Transfer (T/T), and Documents against Payment (D/P).
The current listed wholesale price for Residual Current Circuit Breakers from ABL-Sursum is $1285,./Unit on FOB terms from Germany. Prices may vary depending on order volume, packaging, and destination. For the most accurate bulk quote, send a direct RFQ to ABL-Sursum through EximNext.
The supplier, ABL-Sursum, has set a Minimum Order Quantity (MOQ) of 1 Unit for Residual Current Circuit. For sample requests or smaller trial orders, contact the supplier directly through our platform's inquiry system.
For international shipping and customs clearance, Residual Current Circuit Breakers is classified under HS Code 8536.30. Buyers should verify their local customs regulations to determine applicable import duties and taxes for this classification.
To import Residual Current Circuit from Germany, negotiate shipping terms (FOB, CIF, or EXW) directly with ABL-Sursum. Ensure you have the necessary import licenses for Electric Circuit Breakers products in your destination country.
Yes, ABL-Sursum is a verified supplier on EximNext. You can view their complete company profile, business registration details, certifications, and export history before placing a bulk order.
The key specifications for Residual Current Circuit Breakers supplied by ABL-Sursum include Residual Current Circuit Breaker (RCCB / RCD), 2-Pole (Single-Phase) / 4-Pole (Three-Phase), and 16A, 25A, 32A, 40A, 63A, 100A. For a complete technical data sheet or Certificate of Analysis (COA), send an inquiry directly to the supplier through EximNext.
ABL-Sursum offers Residual Current Circuit with standard export packaging. Custom packaging, private labeling, and OEM/ODM options may also be available for large wholesale orders.
Residual Current Circuit is actively imported by buyers worldwide. Request a destination-specific CIF or CFR quote from ABL-Sursum through our platform.
ABL-Sursum maintains international quality certifications. These ensure that the Residual Current Circuit meets international quality, safety, and regulatory standards required for cross-border trade.
Click "Request Quotation" on this product page, specify your required quantity, preferred shipping terms, and destination country. ABL-Sursum will respond with a detailed wholesale quote including FOB pricing, lead time, and payment options.
Common payment methods include Letter of Credit (L/C), Telegraphic Transfer (T/T), Documents against Payment (D/P), and Escrow services. Confirm accepted terms directly with ABL-Sursum.
Discover more products in Electric Circuit Breakers from verified suppliers worldwide.