Korea 21 Flowmeter — Supplier
About Korea 21 Flowmeter - Water Meter Supplier in South Korea (Republic Of Korea)
South Korea (Republic Of Korea) supplier Korea 21 Flowmeter lists ten active products across water metering, electric power meters and calculators. The catalogue includes electromagnetic flowmeters (model HMF-2110), ultrasonic flowmeters (models HUF 2000N / HUF 2000DN), turbine flow meters, flow computers, and electromagnetic water meters (HMF2100). It also offers energy calculators, one of which is recorded with HS code 9027.89 and housed in stainless steel with electronic components. The product list covers both standalone meters and ancillary calculation devices used in utility measurement.
The electromagnetic flowmeter family is identified without a separate HS code in the data but generally falls under HS chapter 9026 for measuring and testing instruments. Ultrasonic flowmeter entries are similarly grouped within the same chapter. The turbine flow meters are also classified under HS 9026. The energy calculator entry explicitly cites HS 9027.89, which covers other measuring instruments, indicating the product is treated as a precision electronic device. All ten items are presented without additional material specifications beyond the stainless‑steel housing noted for the calculator.
Product Range and Specialties of Korea 21 Flowmeter
Korea 21 Flowmeter’s catalogue comprises electromagnetic flowmeters (HMF‑2110 and generic electromagnetic water meters), ultrasonic flowmeters (HUF 2000N / HUF 2000DN and a generic ultrasonic model), turbine flow meters, a flow computer, and electronic energy calculators. Electromagnetic meters typically comply with IEC 60534‑8‑3, offer accuracy classes from 0.2 % to 1 % of full‑scale, and are available in pipe diameters DN15‑DN2000 with stainless‑steel or ductile‑iron bodies. Ultrasonic transit‑time meters usually achieve 0.5 %‑2 % accuracy, operate at frequencies between 1 MHz and 5 MHz, and can be clamp‑on or flanged for pipe sizes DN15‑DN600. Turbine meters are mechanical devices with accuracy 0.5 %‑2 %, often fabricated from brass or stainless steel for clean‑water applications. Flow computers are built to IEC 61850 standards and support Modbus, Profibus or Ethernet communication. Energy calculators, classified under HS 9027.89, are electronic devices that follow IEC 62052‑11 for safety and typically feature stainless‑steel housings for durability.
Trade and Export Information - Korea 21 Flowmeter
South Korean manufacturers of flow measurement equipment commonly export to Southeast Asian utilities, Middle‑East water authorities, and European industrial sectors. HS 9026.30 is the standard code for electromagnetic, ultrasonic and turbine flow meters, while HS 9027.89 covers electronic calculators and similar instruments. Buyers in the EU and the United States usually require CE marking or UL/NRTL certification, together with an ISO 9001 quality‑management system audit. Export shipments are frequently packed on wooden pallets, loaded in 20‑ft containers (approximately 12 000 kg capacity) or 40‑ft containers for larger orders, and shipped under FOB Busan or CIF major ports such as Rotterdam or Houston. South Korean exporters often provide a Declaration of Conformity for CE and may seek IECEx certification when the meters are destined for hazardous‑area installations.
Sourcing from Korea 21 Flowmeter - Buyer Guidance
When sourcing from Korea 21 Flowmeter, request the latest calibration certificate for each flowmeter model, as well as test reports demonstrating compliance with IEC 60534 for electromagnetic meters and IEC 60534‑9‑2 for ultrasonic devices. Ask for a CE Declaration of Conformity or equivalent NRTL report for the energy calculators, and a material data sheet confirming the stainless‑steel grade (typically SS 304 or SS 316). Verify the communication protocol of the flow computer matches your SCADA system, and obtain sample performance curves that show pressure loss and accuracy across the rated flow range. Typical minimum order quantities are 1‑10 units per model, with lead times of 4‑8 weeks after receipt of a confirmed purchase order and payment of a sample deposit.
Frequently Asked Questions About Korea 21 Flowmeter
What flowmeter models are listed in the catalogue?
The catalogue lists an Electromagnetic Flowmeter (HMF‑2110), a generic Electromagnetic Water Meter (HMF2100), Ultrasonic Flowmeters (HUF 2000N / HUF 2000DN and a generic model), and Turbine Flow Meters.
Which HS codes apply to the listed products?
Electromagnetic, ultrasonic and turbine flow meters fall under HS 9026.30 for measuring instruments, while the Energy Calculator is recorded under HS 9027.89.
What material is used for the Energy Calculator housing?
The Energy Calculator is described as having a stainless‑steel housing with electronic components.
What certifications should a buyer request for the flowmeters?
Buyers should request CE marking or UL/NRTL certification, an ISO 9001 quality‑management certificate, and calibration certificates that reference IEC 60534 standards.
Are sample units available and what is a typical MOQ?
Samples can be supplied; typical minimum order quantities range from one to ten units per model, depending on the specific meter type.
What are the usual lead times for an order?
Lead times are generally 4 weeks for standard models and up to 8 weeks for customized configurations after order confirmation.
How are the products packaged for export?
Products are packed in wooden crates on pallets, suitable for 20‑ft or 40‑ft containers, with moisture‑resistant cushioning for electronic components.
Which regions most frequently import these flow measurement devices from South Korea?
Major import regions include Southeast Asia, the Middle East, and Europe, where utilities and process industries require reliable flow measurement solutions.